Connecting the cabling between the lower arm and swing
NoteAction
xx2000001938
Connect the connectors to each other and snap
them to the cable holders.
1
Cable ties (3 pcs)Secure the cabling with cable ties.2
xx2000001937
Hex socket head cap screw: M3x8
12.9 Lafre 2C2B/FC6.9 (1 pcs).
Connect the functional earth cable with the screw.3
Tightening torque: 0.8 Nm
xx2000001936
Continues on next page
Product manual - CRB 15000 873
3HAC077389-001 Revision: L
© Copyright 2021 - 2023 ABB. All rights reserved.
5 Repair
5.6.3 Replacing the axis-2 joint unit (CRB 15000-5/0.95)
Continued