NoteAction
Guide pin, M5x150: 3HAC087786-
001
Remove two attachment screws and fit two guide
pins to the axis-2 joint unit.
CAUTION
Do not mix the flange screws used for CRB 15000-
5/0.95 and the threaded screws used for CRB
15000-10/1.52 and CRB 15000-12/1.27. Always
use washers together with the threaded screws
for CRB 15000-10/1.52 and CRB 15000-12/1.27.
Illustration is for reference only.
3
Always use guide pins in pairs.
xx2000001951
xx2000001960
xx2000001940
Remove the lower arm attachment screws.
CAUTION
Do not mix the flange screws used for CRB 15000-
5/0.95 and the threaded screws used for CRB
15000-10/1.52 and CRB 15000-12/1.27. Always
use washers together with the threaded screws
for CRB 15000-10/1.52 and CRB 15000-12/1.27.
Illustration is for reference only.
4
xx2000002151
Use two fully threaded attachment screws as re-
moval tools to press the lower arm out of position.
5
Continues on next page