Communication
43
* 6-digit register addressing (400001) is used instead of 5-digit
register addressing (40001) to describe register map. See section
Register Addressing on page 37 for additional information.
** Register addresses of the 32-bit parameters cannot be
accessed by using 5-digit register numbers.
Transparent 32-bit
The Transparent 32-bit communication profile provides unaltered
32-bit access to the configured drive profile.
400052 Native Drive Profile Actual 1
400053 Native Drive Profile Actual 2
400054 DATA IN 1
400055 DATA IN 2
400056 DATA IN 3
400057 DATA IN 4
400058 DATA IN 5
400059 DATA IN 6
400060 DATA IN 7
400061 DATA IN 8
400062 DATA IN 9
400063 DATA IN 10
400064 DATA IN 11
400065 DATA IN 12
400101-409999 Drive Parameter Access (16-bit)
Register Address = 400000 + 100 x Group + Index
Example for Drive Parameter 3.18
400000 + 100 x 3 + 18 = 400318
Register addressing of the 32-bit parameters (not
supported with ACS350 and ACS355):
420000 + 200 x Group + 2 x Index
Example for Drive Parameter 1.27
420000 + 200 x 1 + 2 x 27 = 420254
Register Address*, ** Register Data (16-bit)
400001 Native Drive Profile Control - Least Significant 16-bits
400002 Native Drive Profile Control - Most Significant 16-bits
Register Address*, ** Register Data (16-bit)