FOXCST REFERENCE
FOX61xLEDE1 37
Risk of operating trouble!
Changing the P12 termination mode results in most cases in incompatible
layer rates or number of timeslots.
The channel with its CTP and the assigned connections are deleted
automatically and must be newly created.
Please refer to "1KHW002467 FOX61x TDM Services", section 4.2.2.
8.3.3.2 AP: / unit-x / port-y, Configuration - Synchronization
Table 11: AP: / unit-x / port-y, Configuration - Synchronization
Operation Name Parameter Name Range Description / Details
Synchronization Method None Do not use a synchronization method
SSM-Sa4 Use the selected Sa bit in time slot 0 for the
transport of the synchronization status message
(SSM).
These parameter values are only available with
the termination modes “PCM30C” and
“PCM31C”.
SSM-Sa5
SSM-Sa6
SSM-Sa7
SSM-Sa8
SSI-Sa5 Use the Sa5 bit in time slot 0 for the transport of
the synchronization status indication (SSI).
The SSI method is ABB proprietary and is com-
patible with the FOX51x.
This parameter value is only available with the
termination modes “PCM30”, “PCM30C”,
“PCM31” and “PCM31C”.
QL Transmission Source ESI-1 Synchronization sources are all the PDH clock
sources as they are configured at the AP: /ne,
Configuration - PETS
ESI-2
<PDH Clock Source 1>
<PDH Clock Source 2>
<PDH Clock Source 3>
<PDH Clock Source 4>
Internal
Usage NA No synchronization method has been selected.
CanBeUsed Transmit the QL value of the selected synchroni-
zation source
DoNotUse Transmit the QL value 15, i.e. indicating that the
traffic signal cannot be used as a synchroniza-
tion source.