Parameterization
D184B140U02 FSM4000 93
Parameter Minimum value Maximum value
A
ccidental coil
g
round 10 M 99.9 M
DAC max
100
Design level of the
flowmeter sensor
Nominal diameter A B
DN 1 ... 2
(
1/25 ... 1/12"
)
500 -
DN 3 ... 10
(
1/10 ... 3/8"
)
300 300
DN 15
(
1/2"
)
400 300
DN 20 ... 25
(
3/4 ... 1"
)
400 400
DN 32
(
1 1/4"
)
400 500
DN 40 ... 50
(
1 1/2 ... 2"
)
500 500
DN 65
(
2 1/2"
)
400 300
DN 80
(
3"
)
500 300
DN 100 ... 125
(
4 ... 5"
)
500 600
DN 150
(
6"
)
400 600
DN 200 ... 300
(
8 ... 12"
)
400 700
DN 350 ... 400
(
14 ... 16"
)
500 700
DN 450 ... 1000
(
18 ... 40"
)
700 700
Magn. linearity This value depends on the fluid temperature T
medium
.
T
medium
T
medium
-40 °C
(
-40 °F
)
Factory fingerprint x 0.86
-40 °C
(
-40 °F
)
Factory fingerprint x 0.95
-20 °C
(
-4 °F
)
Factory fingerprint x 0.90
-20 °C
(
-4 °F
)
Factory fingerprint x 1
0 °C
(
32 °F
)
Factory fingerprint x 0.93
0 °C
(
32 °F
)
Factory fingerprint x 1.03
20 °C
(
68 °F
)
Factory fingerprint x 0.95
20 °C
(
68 °F
)
Factory fingerprint x 1.05
60 °C
(
140 °F
)
Factory fingerprint x 1
60 °C
(
140 °F
)
Factory fingerprint x 1.10
90 °C
(
194 °F
)
Factory fingerprint x 1.05
90 °C
(
194 °F
)
Factory fingerprint x 1.16
130 °C
(
266 °F
)
Factory fingerprint x 1.09
130 °C
(
266 °F
)
Factory fingerprint x 1.21
180 °C
(
356 °F
)
Factory fingerprint x 1.14
180 °C
(
356 °F
)
Factory fingerprint x 1.26
SNR (signal-to-noise
ratio
)
60 % of the commissioning fingerprint or a
hi
g
her value, depends on the application.
100 %

Table of Contents