Operation Manual / TPS44-F.. - TPS61-F..
Start-up 3
Oil supply 3.1 Page 37
© Copyright 2016 ABB. All rights reserved.
August 2017HZTL2412_ENRevision F
Oil pressure
The oil pressure in front of the turbocharger must be maintained precisely
to ensure trouble-free operation.
Status for operation Oil pressure in front of
turbocharger
[bar]
Normal operation 2.0 … 4.5
Engine start: cold oil, permissible for maximum
15 minutes
8.0
Engine idling 0.2
Pre- and post-lubrication (engine stopped) 1.0
CAUTION
Prelubrication
Serious machine or property damage might result if the turbocharger is
not supplied with oil when the engine is starting.
τ Activate prelubrication device before starting engine.