Wash down procedure
NoteAction
xx2100001402
User toolsA
Protective devices or equip-
ment
B
Wipe down areaC
Before cleaning,
Use protective devices and equipment to
make sure the painted surfaces of the robot
body (wipe down areas) not exposed dir-
ectly to sprayed detergents, disinfectants
and ejected water.
If user tools are removed from the robot
flange before the cleaning, conduct protect-
ive measures on screw holes to make sure
no intrusion of soils, water, detergents and
disinfectants into the holes during cleaning.
1
Recommended water temperature:
40 - 60°C
Pre-rinse with water for removal of food residues
from to-be-cleaned areas.
2
Make sure no visible residues left.
Detergent: Topax66, concen-
tration (v/v) 2 %
Detergent: Topaz HD1, con-
centration (v/v) 2 %
Foam the surface with detergent Topax66 or To-
paz HD 1.
Use a sprinkling can so that the to-be-cleaned
areas can be covered evenly with sufficient foamy
detergent.
3
Wait 15 minutes.4
Let the detergent work for approx 15 minutes to
retain effective cleaning properties.
Ensure that the cleaning agent does not dry on
the surface.
Recommended water temperature:
40 - 60°C
Rinse thoroughly with water to remove the deter-
gent.
5
Detergent: Topaz AC3, concentra-
tion (v/v) 2 %
Foam the surface with detergent Topaz AC3.
Use a sprinkling can so that the to-be-cleaned
areas can be covered evenly with sufficient foamy
detergent.
6
Wait 15 minutes.7
Let the detergent work for approx 15 minutes to
retain effective cleaning properties.
Ensure that the cleaning agent does not dry on
the surface.
Recommended water temperature:
40 - 60°C
Rinse thoroughly with water to remove the deter-
gent.
8
Detergent: Topactive DES, concen-
tration (v/v) 2 %
Foam the surface with disinfection Topactive DES.
Use a sprinkling can so that the to-be-cleaned
areas can be covered evenly with sufficient foamy
disinfection.
9
Wait 15 minutes.10
Continues on next page
154 Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
3 Maintenance
3.5.2 Cleaning the IRB 1200 with protection type Hygienic
Continued

Table of Contents