Performing the fine calibration procedure
NoteAction
WARNING
Do not fine calibrate the robot without special
equipment used for axis calibration! It would
cause an unsatisfied accuracy in the robot
movement.
1
Choose fine calibration from Calib menu2
On the ABB menu, tap Calibration.
All mechanical units connected to the system are
shown along with their calibration status.
Tap to select the mechanical unit and then tap Calib. Parameters.
en0400001127
3
Tap Fine Calibration....4
A dialog box is displayed, urging you to use ex-
ternal equipment to perform the actual calibration.
Make sure all necessary calibration equipment is
fitted for the axis to be calibrated.
A dialog box is displayed, warning that updating
the revolution counters may change programmed
robot positions:
Tap Yes to proceed.
Tap No to cancel.
Select the check-box for the current axis/axes to
be calibrated.
5
Continues on next page
862 Product manual - IRB 1200
3HAC046983-001 Revision: S
© Copyright 2014 - 2021 ABB. All rights reserved.
5 Calibration
5.6.7 Manual calibration method - calibrating axis 5 and axis 6
Continued