NoteAction
Screw: M4x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Refit the axis-2 cable protector.6
Tightening torque: 2.6 Nm
xx2000001556
Routing the cable package in the lower arm
NoteAction
For robots with protection type Clean Room:1
Clean the joints that have been opened and wipe
the parts free from particles with spirit on a lint
free.
Screw: M4x8 12.9 Lafre
2C2B/FC6.9 (2 pcs)
Refit the connector plate to the cable package.2
Tightening torque: 2.6 Nm
xx2000001554
Continues on next page
176 Product manual - IRB 1300
3HAC070390-001 Revision: G
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.3.1 Replacing the cable package
Continued