Refitting the hall sensor
Use these procedures to refit the hall sensor.
Refitting the axis-7 hall sensor
NoteAction
Hall sensor with attachment for axis 7:
3HAC052447-001
Refit the hall sensor with two screws and
washers.
1
Screws: 3HAB3409-241 (2 pcs).
Tightening torque: 0.8 Nm.
xx1500000462
xx1500000509
Connect the hall sensor connector P3.
Put back the hall sensor interface board
(HSIB) in place.
2
Screws: 3HAB3409-233 (2 pcs).Refit the cable bracket.3
Tightening torque: 0.8 Nm.
xx1500000508
Continues on next page
252 Product manual - IRB 14000
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
4 Repair
4.5.3 Replacing the axis-7 hall sensor
Continued