Removing the fan
Use this procedure to remove the fan.
Preparations before removing the fan
NoteAction
DANGER
Turn off all:
electric power supply
air pressure supply
to the robot, before starting the repair work on the
robot.
1
xx1500000370
Check if there is enough space beneath the robot
to remove the bottom cover. If not:
Place the robot in its calibration position.
Remove the fastening screws.
Put the robot on a flat and stable surface
in the following position:
2
Removing the fan
NoteAction
DANGER
Make sure that all supplies for electrical power
and air pressure are turned off.
1
xx1500000310
Remove the bottom cover.
CAUTION
Be careful not to damage the cables.
2
Disconnect the fan connector:
E1.XS1
3
Continues on next page