Removing the fieldbus adapter
NoteAction
DANGER
Make sure that all supplies for electrical power
and air pressure are turned off.
1
ELECTROSTATIC DISCHARGE (ESD)
The unit is sensitive to ESD. Before handling the
unit please read the safety information in the
section WARNING - The unit is sensitive to ESD!
on page 55
2
(Depending on which connection is installed)3
Disconnect the connector:
Profibus/S: A32.2
Ethernet/IP/S: A32.1
ProfiNet/S: A32.3
xx0700000193
A Attachment screw (2 pcs)
B Fastening mechanism
Loosen the attachment screws (2 pcs) on front of
the fieldbus adapter to release the fastening
mechanism.
Note
Do not remove the attachment screws, only loosen
them.
4
A
xx1500001755
Grip the loosened attachment screws and gently
pull the fieldbus adapter straight out.
5
Continues on next page
406 Product manual - IRB 14000
3HAC052983-001 Revision: D
© Copyright 2015 - 2016 ABB. All rights reserved.
4 Repair
4.7.16 Replacing the fieldbus adapter
Continued