EasyManua.ls Logo

ABB IRB 2600ID-8/2.0 - Page 336

ABB IRB 2600ID-8/2.0
454 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
InformationAction
Push the cables to motor axis 6 into the
upper arm tube.
6
R4.MP5
R4.FB5
xx1400002576
IRB 2600, motor type B
Connect connectors R4.MP5 and R4.FB5
to motor axis 5.
7
xx1000000998
IRB 2600, motor type A
Connect the connectors to motor axis 5.
8
Parts:
A Bracket
B Attachment screws (2 pcs)
C Connectors to motor axis 5
D Motor axis 5
xx1000001006
Apply flange sealing (Loctite 574) on the
surface where the cover shall be fitted. See
figure!
9
Part:
A Flange sealing (Loctite 574)
Continues on next page
336 Product manual - IRB 2600
3HAC035504-001 Revision: Q
© Copyright 2009-2018 ABB. All rights reserved.
4 Repair
4.7.3 Replacing motor axis 5 - IRB 2600ID
Continued