Extra equipment connections
Connections to the:
• air hose ( 3/8") is located on the front part of the upper arm and at the base.
Max. 8 bar. Inner diameter of the air hose: 9.5 mm.
Number of signals, customer connections option Parallel&Air (803-1):
• 23 (50V, 0.5A)
• 9 (300V, 2A). 8 are double crimped in R1.CP/CS and 1 is only accessible in
the robot base.
• 1 protective ground
Number of signals, customer connections option Ethernet, Parallel&Air (803-2)
and DeviceNet, Parallel&Air (803-3):
• 8 (50V, 0.5A)
• 3 (300V, 2A)
• 2 DeviceNet
• 4 EtherNet
• 1 protective ground
Number of signals, customer connections option Profibus, Parallel&Air (803-4):
• 8 (50V, 0.5A)
• 2 (300V, 2A)
• 2 Profibus
• 1 protective ground
Connection sets
To connect power and signal conductors to the robot base/upper arm connectors,
the following parts are recommended.
ContentArt. no.ConnectorConnection
set
• Sockets for cable area of 0.14-2.5
mm²
• Hood foundry
• Hinged frame, hood
• Multicontact-module, female
3HAC16667-1R1.CP/CSPROC1 on
base
• Hose coupling
• M12 connector, male
3HAC033181-001R1.ETHER-
NET
Connector set
on base
• Pins for cable area 0.21 - 0.93
mm
2
• Bottle shaped shrinking hose
• Angle shaped shrinking hose
• Hose coupling
3HAC025396-001R2.CP/R2.CSR2.CP/R2.CS
• Pins for cable area 0.21 - 0.93
mm
2
• Bottle shaped shrinking hose
• Angle shaped shrinking hose
3HAC070439-001R2.ETHER-
NET
Connector set
upper arm
Continues on next page
110 Product manual - IRB 2600
3HAC035504-001 Revision: AD
© Copyright 2009-2023 ABB. All rights reserved.
2 Installation and commissioning
2.8.2 Customer connection on robot
Continued