EasyManua.ls Logo

ABB IRB 2600ID - Page 159

ABB IRB 2600ID
466 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
NoteAction
CAUTION
The gearbox can contain an excess of pressure
that can be hazardous. Open the oil plug care-
fully in order to let out the excess pressure.
3
xx1800001136
Valid for IRB 2600-20/1.65 type C, IRB 2600-
12/1.65 type C:
Remove the protective cap from the oil nipple
and connect the oil dispenser.
4
xx1800001137
Valid for IRB 2600-20/1.65 type C, IRB 2600-
12/1.65 type C:
Remove the plug from the vent hole.
Note
The vent hole is opened to let out air during the
filling process.
5
Different position due to design differ-
ences:
Valid for IRB 2600-20/1.65, IRB 2600-12/1.65,
IRB 2600-12/1.85, IRB 2600ID-15/1.85, IRB
2600ID-8/2.0:
6
xx1800001137
Open the oil plug, filling.
xx1800001139
Continues on next page
Product manual - IRB 2600 159
3HAC035504-001 Revision: AD
© Copyright 2009-2023 ABB. All rights reserved.
3 Maintenance
3.4.2 Changing the oil, axis 1 gearbox on floor mounted robots
Continued

Table of Contents

Related product manuals