Grease: Shell Gadus S2, 3HAC042536-001.Place the cable harness spiral into its pos-
ition in the arm house.
2
xx1000001005
Lubricate the cables in the spiral with
grease.
Note
Do not cut the strap used as transport
protection of the cable harness spiral at
this point!
Parts:
A Cable harness spiral
B Attachment screws (8 pcs) M8x25
quality Steel 12.9 Gleitmo
xx1000001006
Apply flange sealant on the surface where
the cover shall be fitted. See figure!
3
Part:
A Flange sealant: Loctite 574, -
Continues on next page
Product manual - IRB 2600 233
3HAC035504-001 Revision: AD
© Copyright 2009-2023 ABB. All rights reserved.
4 Repair
4.3.3 Replacing the cable harness in the upper arm - IRB 2600ID