Removing gearbox axis 1
Use this procedure to remove the gearbox.
NoteAction
Decide which calibration routine to use, and
take actions accordingly prior to beginning
the repair procedure.
1
How to drain the oil from the gearbox is
described in section:
Changing the oil, axis 1 gearbox
on floor mounted robots on
page 153
Drain the oil from the gearbox.2
Jog the robot to:
Axis 1: 0°
Axis 2:
Axis 3: -10°
Axis 4:
Axis 5:
Axis 6:
3
DANGER
Turn off all:
electric power supply
hydraulic pressure supply
air pressure supply
to the robot, before entering the safeguarded
space.
4
See Removing motors on page 307.Remove the axis-1 motor.5
See Removing the base on page 297.Remove the complete arm system from the
base and lay down the robot on its side.
6
xx1800000593
Continues on next page
368 Product manual - IRB 2600
3HAC035504-001 Revision: AD
© Copyright 2009-2023 ABB. All rights reserved.
4 Repair
4.8.1 Replacing gearbox axis 1
Continued

Table of Contents