4 Repair
4.3.7. Replacement of air nipple and hose (Foundry Prime)
2693HAC023082-001 Revision: E
© Copyright 2004-2008 ABB. All rights reserved.
Procedure
The following procedures details how to replace the Foundry Prime air nipples and hose. The
pos. no. in following procedures correspond to the illustration in Hose lenghts on page 268
and the table in Required equipment on page 268
Action Note/Illustration
<<
DANGER!
Turn off all electric power, hydraulic and
pneumatic pressure supplies to the robot.
Localise the damaged hose or air
connector, and Continue to replace the
damaged hose route the hose according to
the following illustrations
Connection at base.
xx0600003042
Axis 1
xx0600003043
Continued
Continues on next page

Table of Contents