3 Maintenance
3.3.8. Inspection, cable harness
3HAC020993-001 Revision: G138
© Copyright 2004-2008 ABB. All rights reserved.
2. Make an overall visual inspection of the cable
harness, in order to detect wear and damage.
3. Check the attachments at the rear of the
upper arm and in the upper arm tube.
Check the connectors at the cable harness
division. Make sure the attachment plate is
not bent or in other way damaged.
Shown in the figure Location of cabling
axes 5-6 on page 137.
4.
note
If the manipulator is used in a Foundry Prime
application, check the cables for cracks in
insulation.
Shown in the figure Location of cable
harness, axes 1-4 on page 135.
5. Replace the cable harness if wear, cracks or
damage is detected.
Detailed in section Replacement of
cable harness, axes 5-6 on page 225!
Action Note
Continued

Table of Contents