NoteAction
xx1200000955
IRB 6700 - 235/2.65, IRB 6700 - 205/2.80,
IRB 6700 - 175/3.05, IRB 6700 - 150/3.20,
IRB 6700 - 200/2.60, IRB 6700 - 155/2.85
Inspect the oil level at the vent hole (level
plug).
7
xx1500001645
IRB 6700 - 300/2.70, IRB 6700 - 245/3.00
Required oil level is: 0 - 20 mm below the
oil plug hole.
More information is found in Inspecting the
oil level in axis-3 gearbox on page 127.
Remove the oil dispenser.8
Refit the protective cap on the nipple.
Tightening torque: 24 NmRefit the level plug.9
DANGER
Make sure all safety requirements are met
when performing the first test run. These
are further detailed in the section First test
run may cause injury or damage on
page 26.
10
Product manual - IRB 6700 175
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
3 Maintenance
3.4.4 Changing oil, axis-3 gearbox