NoteAction
xx1300000656
Remove the cable gland cover by perform-
ing the following steps:
1 Open the inner screw a little (the one
the arrow is pointing at). No need to
remove this screw from the motor.
2 Remove the outer screw.
3 Slide the cable gland cover away
from the inner screw. Make sure the
gasket is not damaged.
Tip
Make a note in which direction the cable
exit hole is facing, if the motor will be re-
moved too. The motor shall be refitted in
the same position.
5
Use caution and pull out the motor cables.6
Disconnecting the axis-3 and axis-4 motor cables
NoteAction
DANGER
Make sure that all supplies for electrical
power, hydraulic pressure, and air pressure
are turned off.
1
xx1200001135
Unscrew the attachment screws and
washers and remove the motor cover.
2
Continues on next page
Product manual - IRB 6700 239
3HAC044266-001 Revision: N
© Copyright 2013 - 2018 ABB. All rights reserved.
4 Repair
4.4.1 Removing the cable harness