Check the oil level.
Required oil level is: 53-63 mm below the
machined surface at the oil plug hole.
Alternative measurement; required oil level
at vent hole is: 24 mm ± 5 mm below the
oil plug hole
xx2300000001
5
Type of oil and total amount is detailed in
Technical reference manual - Lubrication
in gearboxes.
Add or drain oil, if required.6
Further information about how to drain or
fill with oil is found in section Changing the
oil in axis-1 gearbox on page 138.
O-ring, G 1/2": 3HAC061327-059Refit the oil plug with a new o-ring.7
Tightening torque: 24 Nm.
xx2200001795
DANGER
Make sure all safety requirements are met
when performing the first test run. See Test
run after installation, maintenance, or repair
on page 94.