NoteAction
xx2200001816
Check the oil level.
Rotate axis 3 up to 5°, if needed, to achieve
correct oil level measurement.
Required oil level: in level with the oil plug
hole when axis 3 is in position +10° to +5°.
7
DANGER
Turn off all:
• electric power supply
• hydraulic pressure supply
• air pressure supply
to the robot, before entering the safe-
guarded space.
8
Type of oil and total amount is detailed in
Technical reference manual - Lubrication
in gearboxes.
Add or drain oil, if required.9
Further information about how to drain or
fill with oil is found in section Changing the
oil in axis-3 gearbox on page 149.
O-ring, G 1/2": 3HAC061327-059Refit the oil plug with a new o-ring.10
Tightening torque: 24 Nm.
xx2100002064
Continues on next page
Product manual - IRB 6710 125
3HAC085695-001 Revision: A
© Copyright 2023 ABB. All rights reserved.
4 Maintenance
4.3.9 Inspecting the oil level in axis-3 gearbox
Continued