Note/IllustrationAction
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 43.
2
xx2100000318
xx1900002330
Hook up the Ethernet extension switch
to the bracket and then push the switch
into position.
Note
During the installation, there should be
no gap between the upper surface of the
Ethernet extension switch and the lower
surface of highest bracket on the main
computer.
xx1800000972
3
Reconnect:
K2.X2 - K4.X8, A2.X1
K4.X7 - K5.1.X5/K3.1.X5
K4.X6 - A2.X4
4
Concluding procedure
Note/IllustrationAction
Perform the function tests to verify that
the safety features work properly, see
Function tests on page 166.
1
Product manual - OmniCore V250XT 123
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
3 Installation and commissioning
3.7.3 Installing the Ethernet extension switch
Continued

Table of Contents

Related product manuals