EasyManua.ls Logo

ABB OmniCore V250XT - Page 127

ABB OmniCore V250XT
456 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Note/IllustrationAction
For DSQC 609:Refit the end clamp besides the power
supply.
2
xx1900001907
For DSQC 634:
xx1900002443
Connect:
T5.X1-A1.X7Terminal block
T8.X1-A1.X15Terminal block
T6.X1-A1.X7Terminal block
T9.X1-A1.X15Terminal block
T5.X2-24VTerminal block
T8.X2-24VTerminal block
T6.X2-24VTerminal block
T9.X2-24VTerminal block
3
Concluding procedure
Note/IllustrationAction
Perform the function tests to verify that
the safety features work properly, see
Function tests on page 166.
1
Product manual - OmniCore V250XT 127
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
3 Installation and commissioning
3.7.4 Installing the power supply optional device
Continued