Note/IllustrationAction
xx1900001885
Refit the assembly onto the mounting
plate.
3
xx1900001878
Fasten the assembly with the screws.4
Reconnect all the connectors on as-
sembly of the robot signal exchange
proxy, ethernet extension-seven port
switch (option), ABB ability™ connected
services, and main computer.
5
For the robot signal exchange proxy:
K2.X8 - A2.X6
(option): K2.X2 - K4.X8, A2.X1
K2.X12 - A2.K3.X6, A2.K3.X7
K2.X10 - A1.X13
K2.X4 - A1.X9
K2.X3 - K6.X1, A2.K3.X1, K5.1.X4,
K7.X1
K2.X1 - T2.X2
K2.X6, K2.X11 - A1.X2
K2.X7, K2.X22 - Harn. LV robot
power (X1)
K2.X9 & X13 - FlexPendant (X4)
Continues on next page
Product manual - OmniCore V250XT 135
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
3 Installation and commissioning
3.7.5 Installing the fieldbus master
Continued