Cleaning the fine filter (polymeric filter)
The procedure below details how to clean the fine filter, that is option 3005-2 Moist
dust filter.
Note/IllustrationAction
Remove the air filter unit.1
xx2100002583
Remove the polymeric filter element.2
Clean the filter three or four times.3
Note
Do not wring the filter to press out water.
Allow the filter to dry in one of these ways:
Lying flat on a flat surface
Blow with compressed air in opposite
direction of filter airflow.
4
xx2100002583
Insert the polymeric filter element to the filter
and secure with the metallic line.
5
Refit the air filter unit to the cabinet.6
Cleaning the coarse filter (metal mesh)
The procedure below details how to clean the coarse filter, that is option 3005-1
Moist particle filter.
Note
The coarse filter cannot be separated from the filter assembly.
Continues on next page
158 Product manual - OmniCore V250XT
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
4 Maintenance
4.3.1 Cleaning air filter
Continued