Refitting the connected services gateway
Refitting the connected services gateway
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 28.
1
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 43.
2
xx1900002331
Hook up the connected services gateway
to the bracket and push carefully into
position.
Note
During the installation, the gap between
the lower surface of the connected ser-
vices gateway and the upper surface of
the main computer should be zero.
3
Reconnect:
K7.X1 - K2.X3
i
K7.X2 - A2.X5
4
i
For connected services gateway wired, there is no power cable.
Reconnecting the antenna
Note/IllustrationAction
xx2100001054
Insert the cable from the cable grommet.1