Note/IllustrationAction
xx1900002446
Push the buckle of the digital base
slightly and take out the digital base.
2
xx1900002447
Refitting the safety digital base device
Refitting the safety digital base device
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 28.
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 43.
2
xx2100000318
Continues on next page
224 Product manual - OmniCore V250XT
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.2.7 Replacing the safety digital base device
Continued