Refitting the DSQC 609 power supply
Refitting the power supply
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 28.
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 43.
2
xx2100000318
Screws: Cross recessed cheese head screw
M4x8 (1 pcs)
Fit the power supply to the bracket and
fasten it with screw.
3
xx1900001908
Reconnect:
• T5.X1-A1.X7Terminal block
T8.X1-A1.X15Terminal block
• T5.X2-24VTerminal block
T8.X2-24VTerminal block
4
Continues on next page
258 Product manual - OmniCore V250XT
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.2.10 Replacing the power supply
Continued