Note/IllustrationAction
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 43.
2
xx2100000318
xx1900001950
Hang the power supply into the bracket
and push the lower of it until you hear a
clear clicking sound.
3
Reconnect:
T6.X1-A1.X7Terminal block
T9.X1-A1.X15Terminal block
T6.X2-24VTerminal block
T9.X2-24VTerminal block
4
xx1900002443
Refit the end clamp besides the power
supply.
5
Continues on next page
Product manual - OmniCore V250XT 261
3HAC073447-001 Revision: B
© Copyright 2020-2022 ABB. All rights reserved.
5 Repair
5.2.10 Replacing the power supply
Continued

Table of Contents