Loading...
Removing the Ethernet outlet connector with cable
Note/IllustrationAction
xx2100000852
Turn the locking ring anti-clockwise to
remove the connector.
1
Push the Ethernet outlet connector with
cable into the cabinet.
2
Disconnect:
X24 - A2.X3
3
Remove the cables out from the clips in
the cabinet carefully.
Note
Make records about the sequence that
cables are removed. The cables need to
be installed in the same position.
4
Take the Ethernet outlet connector with
cable out from the upper side.
5
Refitting the Ethernet outlet connector with cable
Refitting the Ethernet outlet connector with cable
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 28.
1
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 43.