NoteArticle numberSpare part
DSQC 6093HAC14178-1DSQC 609 power supply
DSQC 6343HAC13398-2DSQC 634 power supply
DSQC 609 and DSQC 6343HAC082083-001Harness PSU 24V
DSQC 609 and DSQC 6343HAC082508-001Harness PSU
3HAB7983-1End clamp
Required tools and equipment
NoteArticle numberEquipment
Content is defined in section
Standard toolkit for controller on
page 424.
-Standard toolkit
-ESD protective wrist band
Required documents
NoteArticle numberDocument
3HAC082020-008Circuit diagram - OmniCore
V400XT
Installing the optional power supply
Preparations
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 29.
1
Opening the door on page 182.Open the door.2
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 45.
3
xx2300001842
Continues on next page
132 Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.7.5 Installing the power supply optional device
Continued