Required tools and equipment
NoteArticle numberEquipment
Content is defined in section
Standard toolkit for controller on
page 424.
-Standard toolkit
-ESD protective wrist band
Required documents
NoteArticle numberDocument
3HAC082020-008Circuit diagram - OmniCore
V400XT
3HAC066561-001Application manual - Conveyor
tracking
Installing the conveyor tracking module
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 29.
1
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 45.
2
xx2300001842
Opening the door on page 182.Open the door.3
Continues on next page
136 Product manual - OmniCore V400XT
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.7.6 Installing the conveyor tracking module (CTM)