EasyManua.ls Logo

ABB OmniCore V400XT - Page 139

ABB OmniCore V400XT
466 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installing cables with the cable grommet assembly
Preparations
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 29.
1
Opening the door on page 182.Open the door.2
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 45.
3
xx2300001842
Removing the slot cover (baseline)
Note/IllustrationAction
xx2100001282
Remove the attachment screws.1
Take out the cover from the inside of the
controller.
2
Continues on next page
Product manual - OmniCore V400XT 139
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
3 Installation and commissioning
3.7.7 Installing the cable grommet assembly
Continued

Table of Contents

Related product manuals