Note/IllustrationAction
Location of wrist strap button:
ELECTROSTATIC DISCHARGE
(ESD)
The unit is sensitive to ESD. Before
handling the unit read the safety inform-
ation in section The unit is sensitive to
ESD on page 45.
3
xx2300001842
Removing the power supply
Note/IllustrationAction
xx1900001907
Remove the end clamp besides the
power supply with a screwdriver.
1
xx1900001908
Disconnect all connectors from the unit
to be replaced.
2
Remove the screw and the power supply.3
Continues on next page
Product manual - OmniCore V400XT 253
3HAC081697-001 Revision: A
© Copyright 2022-2023 ABB. All rights reserved.
5 Repair
5.2.12 Replacing the power supply
Continued