Refitting the air filter
Refitting the polymeric filter element
The procedure below details how to refit the polymeric filter element (option 3005-2
Moist dust filter).
Note/IllustrationAction
xx2100002583
Insert the polymeric filter element to the
filter and secure with the metallic line.
1
Refitting the air filter
Note/IllustrationAction
DANGER
Before doing any work inside the cabinet,
disconnect the mains power. For more
information, see Electrical safety on
page 29.
1
Refit the air filter unit to the cabinet.2
Concluding procedure
Note/IllustrationAction
Perform the function tests to verify that
the safety features work properly, see
Function tests on page 171.
1