9.16 Installing the compressor casing
Fitting the wall insert and the diffuser
Fig.38: Fitting the wall insert and the diffuser
Product Size Tightening torque [Nm]
Power2 340-H LP M6 8
Table46: Tightening torque (79041)
1. Fit new O-ring(77005) (see Spare parts 100).
2. Install the wall insert(77000) into the compressor casing.
3. Secure the diffuser(79000) with fixing discs(79040) and new screws(79041).