68 Electrical installation
Connection diagrams for the environmental sensors
Connect the environmental sensors as follows:
Model Type Connection diagram Connections
PVI-AEC-IRR
PVI-AEC-RAD-13TC
Irradiation
sensor
1. X73, AI3+
2. Control board X1, pin 4, +24 V
DC
3. X73, AI3-
Control board X1, pin 5, GND
PVI-AEC-IRR-T
PVI-AEC-RAD-13TC-T
Irradiation
sensor with
cell temp.
sensor
1. X72, AI2+
2. X73, AI3+
3. Control board X1, pin 4, +24 V
DC
4. X72, AI2-
X73, AI3-
Control board X1, pin 5, GND
PVI-AEC-T1000-INTEGR Ambient
temp.
sensor with
integrated
converter
1. X72, AI2+
2. Control board X1, pin 4, +24 V
DC
3. X72, AI2-
Control board X1, pin 5, GND
PVI-AEC-T100-ADH Adhesive
PT100
module
temp.
sensor
1. X71, AI1+
2. X74, AO+
3. X71, AI1-
4. X74, AO-
PVI-AEC-T1000-BOX PT1000
ambient
temperature
sensor
1. X71, AI1+
2. X74, AO+
3. X71, AI1-
4. X74, AO-