7 - Appendix
Type c ode PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US
Mechanical specifications
Nominal output power
3000W 3600W
3300
W
3800W 4200W
Maximum output power wattage
3000
W
3300
1
W
3300
1
W
3600
W
4000
1
W
4000
1
W
3300
W
4200
1
W
4200
1
W
4200
W
4600
1
W
4600
1
W
Rated grid AC voltage 208V 240V 277V 208V 240V 277V 208V 240V 277V 208V 240V 277V
Input side (DC)
Number of independent MPPT channels 2 2 2 2
Maximum usable power for each channel 2000W 3000W 3000W 3000W
Absolute maximum voltage (Vmax) 600V
Start-up voltage (Vstart) 200V (adj. 120-350V)
Full power MPPT voltage range 160-530V 120-530V 140-530V 140-530V
Operating MPPT voltage range 0.7 x Vstart - 580V (>=90V)
Maximum current (Idcmax) for both MPPT in
parallel
20A 32A 32A 32A
Maximum usable current per channel 10A 16A 16A 16A
Maximum short circuit current limit per
channel
12.5A 20.0A 20.0A 20.0A
Number of wire landing terminals per channel 2 pairs
Array wiring termination Terminal block, pressure clamp, AWG10-AWG4
Output side (DC)
Grid connection type
1Ø/
2W
Split-
Ø/3W
1Ø/
2W
1Ø/
2W
Split-
Ø/3W
1Ø/
2W
1Ø/
2W
Split-
Ø/3W
1Ø/
2W
1Ø/
2W
Split-
Ø/3W
1Ø/
2W
Adjustable voltage range (Vmin-Vmax) (V)
183 -
228V
211 -
264V
244-
304V
183-
228V
211-
264V
244-
304V
183-
228V
211-
264V
244-
304V
183-
228V
211-
264V
244-
304V
Grid frequency 60Hz
Adjustable grid frequency range 57-60.5Hz
Maximum current (I
ac,max
)
14.5
A
RMS
14.5
A
RMS
12.0
A
RMS
17.2
A
RMS
16.0
A
RMS
16.0
A
RMS
16.0
A
RMS
16.0
A
RMS
16.0
A
RMS
20.0
A
RMS
20.0
A
RMS
20.0
A
RMS
Power factor > 0.995
Total harmonic distortion at rated power < 2%
Grid wiring termination type Terminal block, Pressure clamp, AWG10-AWG4
Input protection devices
Reverse polarity protection Yes
Over-voltage protection type Varistor, 2 for each channel
PV array ground fault detection Pre start-up Riso and Dynamic GFDI (requires floating arrays)
Output protection devices
Anti-islanding protection Meets UL 1741/IEEE1547 requirements
Over-voltage protection type Varistor, 2
(L
1
- L
2
/ L
1
- G)
Maximum AC OCPD Rating 20A
RMS
20A
RMS
15A
RMS
25A
RMS
20A
RMS
20A
RMS
20A
RMS
20A
RMS
20A
RMS
25A
RMS
25A
RMS
25A
RMS
Efficiency
Maximum efficiency 96.9% 97% 97% 97%
CEC efficiency 96%
Operating performance
Night time consumption < 0.6W
RMS
Stand-by consumption < 8W
RMS
Communication
User-interface 16 characters x 2 lines LCD display
Remote monitoring (1xRS485 incl.) VSN700 Data Logger (opt.)
Environmental
Ambient air operating temperature range -13°F to +140°F with derating above 122°F (50°C)
Ambient air storage temperature range -40°F to +176°F (-40°C to +80°C)
Relative humidity 0-100% RH condensing
Acoustic noise emission level < 50 db (A) @1m
Mechanical specifications
Enclosure rating NEMA 4X
Cooling Natural convection
Dimensions (H x W x D) 33.8 x 12.8 x 8.7in (859 x 325 x 222mm )
Weight <47.3lb (21.3kg)
Shipping weight < 60lb (27.0kg)
Mounting system Wall bracket
Conduit connections
2
Trade size KOs (2ea x 1/2”) and (2ea x 1-1/4”, 3 places side, front, rear)
Side: (2) plugged 3/4” openings, (2) Concentric KOs 3/4”, 1”
Back: (4) Concentric EKOs 3/4”, 1”
DC switch rating (per contact) (A/V) 25/600
Safety
Isolation level Transformerless (floating array)
Safety and EMC standard
UL 1741, IEE1547, IEE1547.1, CSA-C22.2N. 107.1-01, UL1998 UL 1699B, FCC Part 15
Class B
Safety Approval
c
CSA
us
Warranty
Standard warranty 10 years
Extended warranty 15 & 20 years
Available models
Standard - with DC switch - floating Array PVI-3.0-OUTD-US PVI-3.6-OUTD-US PVI-3.8-OUTD-US PVI-4.2-OUTD-US
With DC switch, wiring box and arc fault detector and
interruptor
PVI-3.0-OUTD-S-US PVI-3.6-OUTD-S-US PVI-3.8-OUTD-S-US PVI-4.2-OUTD-S-US
Extended Warranty
PVI-3.0-OUTD-S-
US-A
PVI-3.6-OUTD-S-
US-A
PVI-3.8-OUTD-S-
US-A
PVI-4.2-OUTD-S-
US-A
2. When equipped with optional DC switch and wiring box
All data is subject to change without notice