0xA CS IEC 61850 name SA name Description Values
2072 2.12 .RsSprChaTm.Oper.ctlVa
l
Reset CB spring charge time 1=Reset
LD0.RESCMMXU1
2073 2.13 .RecRs.Oper.ctlVal Reset Io (1) max demands 1=Reset
LD0.RESVMMXU1
2074 2.14 .RecRs.Oper.ctlVal Reset Uo (1) max demands 1=Reset
2.5.2 CTRL.CBCSWI1 Circuit breaker control (1)
Table 182: CTRL.CBCSWI1 Circuit breaker control (1)
0xA CS IEC 61850 name SA name Description Values
CTRL.CBCSWI1
2048 1.00 .Pos.Oper.ctlVal Select open 1=Select
2049 1.01 .Pos.Oper.ctlVal Select close 1=Select
2050 1.02 .Pos.Oper.ctlVal Cancel selection 1=Cancel
2051 1.03 .Pos.Oper.ctlVal Execute selection 1=Execute
2052 1.04 .Pos.Oper.ctlVal Direct open 1=Open
2053 1.05 .Pos.Oper.ctlVal Direct close 1=Close
2.5.3 CTRL.DCXSWI1 Disconnector control (1) – 29DS-1
Table 183: CTRL.DCXSWI1 Disconnector control (1) – 29DS-1
0xA
CS IEC 61850 name SA name Description Values
CTRL.DCCSWI1
2144 7.00 .Pos.Oper.ctlVal Select open 1=Select
2145 7.01 .Pos.Oper.ctlVal Select close 1=Select
2146 7.02 .Pos.Oper.ctlVal Cancel selection 1=Cancel
2147 7.03 .Pos.Oper.ctlVal Execute selection 1=Execute
2148 7.04 .Pos.Oper.ctlVal Direct open 1=Open
2149 7.05 .Pos.Oper.ctlVal Direct close 1=Close