Table 2. Supported functions
Function IEC 61850 A B C D E F G H
Protection
Three-phase non-directional overcurrent
protection, low stage
PHLPTOC1
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
PHLPTOC2
1
LV
1
LV
1
LV
1
LV
1
LV
1
LV
1
LV
1
LV
Three-phase non-directional overcurrent
protection, high stage
PHHPTOC1
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
PHHPTOC2
1
LV
1
LV
1
LV
1
LV
1
LV
1
LV
1
LV
1
LV
Three-phase non-directional overcurrent
protection, instantaneous stage
PHIPTOC1
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
PHIPTOC2
1
LV
1
LV
1
LV
1
LV
1
LV
1
LV
1
LV
1
LV
Non-directional earth-fault protection, low stage EFLPTOC1
1
HV
1
HV 1)
1
HV
1
HV 1)
EFLPTOC2
1
LV
1
LV 2)
1
LV
1
LV 2)
Non-directional earth-fault protection, high
stage
EFHPTOC1
1
HV
1
HV 1)
1
HV
1
HV 1)
EFHPTOC2
1
LV
1
LV 2)
1
LV
1
LV 2)
Negative-sequence overcurrent protection NSPTOC1
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
NSPTOC2
1
LV
1
LV
1
LV
1
LV
1
LV
1
LV
1
LV
1
LV
Residual overvoltage protection ROVPTOV
2
HV
2
HV
2
HV
2
HV
Three-phase undervoltage protection PHPTUV
2
HV
2
HV
2
HV
2
HV
Three-phase overvoltage protection PHPTOV
2
HV
2
HV
2
HV
2
HV
Three-phase thermal overload protection, two
time constants
T2PTTR
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
Stabilized and instantaneous differential
protection for two-winding transformers
TR2PTDF 1 1 1 1 1 1 1 1
Numerically stabilized low-impedance restricted
earth-fault protection
LREFPNDF
1
HV
1
LV
1
HV
1
LV
High-impedance based restricted earth-fault
protection
HREFPDIF
1
HV
1
LV 3)
1
HV
1
LV 3)
Circuit breaker failure protection CCBRBRF
1
HV 1)
1
HV 1)
1
HV 1)
1
HV 1)
1
HV 1)
1
HV 1)
1
HV 1)
1
HV 1)
Master trip TRPPTRC 2
(3)
4)
2
(3)
4)
2
(3)
4)
2
(3)
4)
2
(3)
4)
2
(3)
4)
2
(3)
4)
2
(3)
4)
Arc protection ARCSARC
(3)
LV 5)
(3)
LV 5)
(3)
LV 5)
(3)
LV 5)
(3)
LV 5)
(3)
LV 5)
(3)
LV 5)
(3)
LV 5)
Multipurpose protection MAPGAPC 18 18 18 18 18 18 18 18
Control
Circuit-breaker control CBXCBR
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
Disconnector control DCXSWI 2 2 2 2 2 2 2 2
Earthing switch control ESXSWI 1 1 1 1 1 1 1 1
Disconnector position indication DCSXSWI 3 3 3 3 3 3 3 3
Earthing switch indication ESSXSWI 2 2 2 2 2 2 2 2
Tap changer position indication TPOSYLTC 1 1 1 1 1 1 1 1
Condition monitoring and supervision
Circuit-breaker condition monitoring SSCBR
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
Trip circuit supervision TCSSCBR 2 2 2 2 2 2 2 2
Fuse failure supervision SEQSPVC 1 1 1 1
Runtime counter for machines and devices MDSOPT 1 1 1 1 1 1 1 1
Measurement
Disturbance recorder RDRE 1 1 1 1 1 1 1 1
Load profile record LDPRLRC 1 1 1 1 1 1 1 1
Fault record FLTRFRC 1 1 1 1 1 1 1 1
Three-phase current measurement CMMXU1
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
CMMXU2
1
LV
1
LV
1
LV
1
LV
1
LV
1
LV
1
LV
1
LV
Sequence current measurement CSMSQI1
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
1
HV
Residual current measurement RESCMMXU1
1
HV
1
HV
1
HV
1
HV
RESCMMXU2
1
LV
1
LV
1
LV
1
LV
Three-phase voltage measurement VMMXU
1
HV
1
HV
1
HV
1
HV
Residual voltage measurement RESVMMXU
1
HV
1
HV
1
HV
1
HV
Sequence voltage measurement VSMSQI
1
HV
1
HV
1
HV
1
HV
Three-phase power and energy measurement PEMMXU
1
HV
1
HV
1
HV
1
HV
Transformer Protection and Control
1MRS756891 M
RET615
Product version: 5.0 FP1
ABB 13