Function IEC 61850 IEC 60617
ANSI/C37.2 -2008
REF620 REM620 RET620
Circuit breaker failure protection, instance 3 CCBRBRF3 3I>/Io>BF (3) 50BF (3)
Three-phase inrush detector, instance 1 INRPHAR1 3I2f> INR
Master trip, instance 1 TRPPTRC1 Master Trip (1) 86/94-1 86/94-1 86/94-1
Master trip, instance 2 TRPPTRC2 Master Trip (2) 86/94-2 86/94-2 86/94-2
Master trip, instance 3 TRPPTRC3 Master Trip (3) 86/94-3
86/94-3
2)
86/94-3
Master trip, instance 4 TRPPTRC4 Master Trip (4)
86/94-4
2)
Master trip, instance 5 TRPPTRC5 Master Trip (5)
86/94-5
2)
Master trip, instance 6 TRPPTRC6 Master Trip (6)
86/94-6
2)
Master trip, instance 7 TRPPTRC7 Master Trip (7)
86/94-7
2)
Master trip, instance 8 TRPPTRC8 Master Trip (8)
86/94-8
2)
Arc protection, instance 1 ARCSARC1 ARC (1) AFD-1 AFD-1 AFD-1(1)
Arc protection, instance 2 ARCSARC2 ARC (2) AFD-2 AFD-2 AFD-2(2)
Arc protection, instance 3 ARCSARC3 ARC (3) AFD-3 AFD-3 AFD-3(3)
High-impedance fault detection PHIZ1 PHIZ1 HIZ
Cable fault detection RCFD1 CFD CFD
Load shedding and restoration, instance 1 LSHDPFRQ1 UFLS/R (1) 81LSH-1 81LSH-1(1)
Load shedding and restoration, instance 2 LSHDPFRQ2 UFLS/R (2) 81LSH-2 81LSH-2(1)
Load shedding and restoration, instance 3 LSHDPFRQ3 UFLS/R (3) 81LSH-3(1)
Load shedding and restoration, instance 4 LSHDPFRQ4 UFLS/R (4) 81LSH-4(1)
Load shedding and restoration, instance 5 LSHDPFRQ5 UFLS/R (5) 81LSH-1(2)
Load shedding and restoration, instance 6 LSHDPFRQ6 UFLS/R (6) 81LSH-2(2)
Load shedding and restoration, instance 7 LSHDPFRQ7 UFLS/R (7) 81LSH-3(2)
Load shedding and restoration, instance 8 LSHDPFRQ8 UFLS/R (8) 81LSH-4(2)
RTD based thermal protection, instance 1 MAPGAPC1 ThA> ThB>(1) 38-1 38-1
RTD based thermal protection, instance 2 MAPGAPC2 ThA> ThB>(2) 38-2 38-2
RTD based thermal protection, instance 3 MAPGAPC3 ThA> ThB>(3) 38-3 38-3
RTD based thermal protection, instance 4 MAPGAPC4 ThA> ThB>(4) 38-4
RTD based thermal protection, instance 5 MAPGAPC5 ThA> ThB>(5) 38-5
RTD based thermal protection, instance 6 MAPGAPC6 ThA> ThB>(6) 38-6
RTD based thermal protection, instance 7 MAPGAPC7 ThA> ThB>(7) 38-7
RTD based thermal protection, instance 8 MAPGAPC8 ThA> ThB>(8)
38-8
2)
RTD based thermal protection, instance 9 MAPGAPC9 ThA> ThB>(9)
38-9
2)
RTD based thermal protection, instance 10 MAPGAPC10
ThA>
ThB>(10)
38-10
2)
RTD based thermal protection, instance 11 MAPGAPC11
ThA>
ThB>(11)
38-11
2)
RTD based thermal protection, instance 12 MAPGAPC12
ThA>
ThB>(12)
38-12
2)
RTD based thermal protection, instance 13 MAPGAPC13
ThA>
ThB>(13)
38-13
2)
RTD based thermal protection, instance 14 MAPGAPC14
ThA>
ThB>(14)
38-14
2)
RTD based thermal protection, instance 15 MAPGAPC15
ThA>
ThB>(15)
38-15
2)
RTD based thermal protection, instance 16 MAPGAPC16
ThA>
ThB>(16)
38-16
2)
RTD based thermal protection, instance 17 MAPGAPC17
ThA>
ThB>(17)
38-17
2)
Table continues on next page
1MAC456939-IB D Section 1
Introduction
620 series ANSI 13
Operation Manual