Function IEC 61850 IEC 60617
ANSI/C37.2 -2008
REF620 REM620 RET620
RTD based thermal protection, instance 18 MAPGAPC18
ThA>
ThB>(18)
38-18
2)
Out of step OOSRPSB1 φ>
78
3)
Power factor, instance 1 MPUPF1 PF< (1)
55-1
3)
Power factor, instance 2 MPUPF2 PF< (2)
55-2
3)
Three-phase underexcitation protection, instance 1 UEXPDIS1 X< (1)
40
3)
Control
Circuit-breaker control, instance 1 CBXCBR1 I <-> O CB (1) 52-1 52 52 (1)
Circuit-breaker control, instance 2 CBXCBR2 I <-> O CB (2) 52-2 52 (2)
Circuit-breaker control, instance 3 CBXCBR3 I <-> O CB (3) 52 (3)
Emergency start-up ESMGAPC1 ESTART 62EST
Autoreclosing, instance 1 DARREC1 O -> I (1) 79-1
Autoreclosing, instance 2 DARREC2 O -> I (2) 79-2
Synchronism and energizing check, instance 1 SECRSYN1 SYNC (1) 25-1
25
3)
Synchronism and energizing check, instance 2 SECRSYN2 SYNC (2) 25-2
Synchronism and energizing check, instance 3 SECRSYN3 SYNC (3) 25-3
Condition monitoring
Circuit-breaker condition monitoring, instance 1 SSCBR1 CBCM (1) 52CM-1 52CM 52CM (1)
Circuit-breaker condition monitoring, instance 2 SSCBR2 CBCM (2) 52CM-2 52CM (2)
Circuit-breaker condition monitoring, instance 3 SSCBR3 CBCM (3) 52CM (3)
Trip circuit supervision, instance 1 TCSSCBR1 TCS (1) TCM-1 TCM-1 TCM-1
Trip circuit supervision, instance 2 TCSSCBR2 TCS (2) TCM-2 TCM-2 TCM-2
Trip circuit supervision, instance 3 TCSSCBR3 TCS (3) TCM-3
Current circuit supervision CCRDIF1 MCS 3I CCM CCM
Advanced current circuit supervision for transformers CTSRCTF1 MCS 3I, I2 MCS 3I, I2
Fuse failure supervision, instance 1 SEQRFUF1 FUSEF (1) 60-1 60 60 (1)
Fuse failure supervision, instance 2 SEQRFUF2 FUSEF (2) 60-2 60 (2)
Runtime counter for machines and devices, instance 1 MDSOPT1 OPTS (1) OPTM-1
Runtime counter for machines and devices, instance 2 MDSOPT2 OPTS (2) OPTM-2
Measurement
Three-phase current measurement, instance 1 CMMXU1 3I IA, IB, IC IA, IB, IC IA, IB, IC (1)
Three-phase current measurement, instance 2 CMMXU2 3I(B) IA, IB, IC (2) IA, IB, IC (2)
Three-phase current measurement, instance 3 CMMXU3 3I(C) IA, IB, IC (3)
Sequence current measurement, instance 1 CSMSQI1 I1, I2, I0 I1, I2, I0 I1, I2, I0 I1, I2, I0 (1)
Sequence current measurement, instance 2 CSMSQI2 I1, I2, I0 (B) I1, I2, I0 (2) I1, I2, I0 (2)
Sequence current measurement, instance 3 CSMSQI3 I1, I2, I0 (C) I1, I2, I0 (3)
Residual current measurement, instance 1 RESCMMXU1 Io IG IG IG
Three-phase voltage measurement, instance 1 VMMXU1 3U VA, VB, VC VA, VB, VC VA, VB, VC (1)
Three-phase voltage measurement, instance 2 VMMXU2 3U (B) VA, VB, VC (2) VA, VB, VC (2)
Residual voltage measurement, instance 1 RESVMMXU1 Uo VG VG VG
Residual voltage measurement, instance 2 RESVMMXU2 Uo(B) VG
Sequence voltage measurement, instance 1 VSMSQI1 U1, U2, U0 V1, V2, V0 V1, V2, V0 V1, V2, V0 (1)
Sequence voltage measurement, instance 2 VSMSQI2 U1, U2, U0 (B) V1, V2, V0 (2) V1, V2, V0 (2)
Three-phase power and energy measurement, instance 1 PEMMXU1 P, E P, E P, E P, E (1)
Three-phase power and energy measurement, instance 2 PEMMXU2 P, E (B) P, E (2)
Current total demand distortion, instance 1 CMHAI1 PQM3I(1) PQI-1
Voltage total harmonic distortion, instance 1 VMHAI1 PQM3U(1) PQVPH-1
Table continues on next page
Section 1 1MAC456939-IB D
Introduction
14 620 series ANSI
Operation Manual