Function IEC 61850 IEC 60617
ANSI/C37.2 -2008
REF620 REM620 RET620
Voltage total harmonic distortion, instance 2 VMHAI2 PQM3U(2) PQVPH-2
Voltage variation, instance 1 PHQVVR1 PQ 3U<>(1) PQSS-1
Voltage unbalance, instance 1 VSQVUB1 PQMUBU(1) PQVUB-1
Voltage unbalance, instance 2 VSQVUB2 PQMUBU(2) PQVUB-2
Load profile, instance 1 LDPMSTA1 LoadProf LoadProf LoadProf LoadProf
Frequency measurement, instance 1 FMMXU1 f f f f
Frequency measurement, instance 2 FMMXU2 f f
Single-phase power and energy measurement, instance 1 SPEMMXU1 SP, SE SP, SE SP, SE SP, SE (1)
Single-phase power and energy measurement, instance 2 SPEMMXU2 SP, SE(B) SP, SE (2)
Tap changer position indication TPOSSLTC1 TPOSM 84T
Other
Minimum pulse timer (2 pcs), instance 1 TPGAPC1 TP (1) TP-1 TP-1 TP-1
Minimum pulse timer (2 pcs), instance 2 TPGAPC2 TP (2) TP-2 TP-2 TP-2
Minimum pulse timer (2 pcs), instance 3 TPGAPC3 TP (3) TP-3 TP-3 TP-3
Minimum pulse timer (2 pcs), instance 4 TPGAPC4 TP (4) TP-4 TP-4 TP-4
Minimum pulse timer (2 pcs, second resolution), instance 1
TPSGAPC1
TPS (1) 62CLD-1
TPS (1)
3)
Minimum pulse timer (2 pcs, second resolution), instance 2
TPSGAPC2
TPS (2) 62CLD-3
TPS (2)
3)
Minimum pulse timer (2 pcs, minute resolution), instance 1
TPMGAPC1
TPM (1) 62CLD-2
TPM (1)
3)
Minimum pulse timer (2 pcs, minute resolution), instance 2
TPMGAPC2
TPM (2) 62CLD-4
TPM (2)
3)
Pulse timer (8 pcs), instance 1 PTGAPC1 PT (1) PT-1 PT-1 PT-1
Pulse timer (8 pcs), instance 2 PTGAPC2 PT (2) PT-2 PT-2 PT-2
Time delay off (8 pcs), instance 1 TOFGAPC1 TOF (1) TOF-1 TOF-1 TOF-1
Time delay off (8 pcs), instance 2 TOFGAPC2 TOF (2) TOF-2 TOF-2 TOF- 2
Time delay off (8 pcs), instance 3 TOFGAPC3 TOF (3) TOF-3 TOF-3 TOF-3
Time delay off (8 pcs), instance 4 TOFGAPC4 TOF (4) TOF-4 TOF-4 TOF- 4
Time delay on (8 pcs), instance 1 TONGAPC1 TON (1) TON -1 TON -1 TON -1
Time delay on (8 pcs), instance 2 TONGAPC2 TON (2) TON -2 TON -2 TON -2
Time delay on (8 pcs), instance 3 TONGAPC3 TON (3) TON -3 TON -3 TON -3
Time delay on (8 pcs), instance 4 TONGAPC4 TON (4) TON -4 TON -4 TON -4
Set reset (8 pcs), instance 1 SRGAPC1 SR (1) SR-1 SR-1 SR-1
Set reset (8 pcs), instance 2 SRGAPC2 SR (2) SR-2 SR-2 SR-2
Set reset (8 pcs), instance 3 SRGAPC3 SR (3) SR-3 SR-3 SR-3
Set reset (8 pcs), instance 4 SRGAPC4 SR (4) SR-4 SR-4 SR-4
Move (8 pcs), instance 1 MVGAPC1 MV (1) MV-1 MV-1 MV-1
Move (8 pcs), instance 2 MVGAPC2 MV (2) MV-2 MV-2 MV-2
Move (8 pcs), instance 3 MVGAPC3 MV (3) MV-3 MV-3 MV-3
Move (8 pcs), instance 4 MVGAPC4 MV (4) MV-4 MV-4 MV-4
Move (8 pcs), instance 5 MVGAPC5 MV (5) MV-5 MV-5 MV-5
Move (8 pcs), instance 6 MVGAPC6 MV (6) MV-6 MV-6 MV-6
Move (8 pcs), instance 7 MVGAPC7 MV (7) MV-7 MV-7 MV-7
Move (8 pcs), instance 8 MVGAPC8 MV (8) MV-8 MV-8 MV-8
Move (8 pcs), instance 9 MVGAPC9 MV (9)
MV-9
2)
Move (8 pcs), instance 10 MVGAPC10 MV (10)
MV-10
2)
Generic control points, instance 1 SPCGGIO1 SPC(1) CNTRL-1 CNTRL-1 CNTRL-1
Generic control points, instance 2 SPCGGIO2 SPC(2) CNTRL-2 CNTRL-2 CNTRL-2
Generic control points, instance 3 SPCGGIO3 SPC(3) CNTRL-3 CNTRL-3 CNTRL-3
Remote generic control points, instance 1 SPCRGGIO1 SRCR(1) RCNTRL-1 RCNTRL-1 RCNTRL-1