Event number Acronyms GSAL mapping English
10042 MAINT_UPDATE_ABORT_FAIL GSAL.Ina Failed to abort firmware update
procedure
10050 MAINT_RECOVERY_ENTER_OK GSAL.Ina Recovery menu entered successfully
10052 MAINT_RECOVERY_ENTER_FAIL GSAL.Ina Failed to enter Recovery menu
10060 MAINT_AUTH_DIS_OK GSAL.Ina Authentication disabled from
maintenance menu successfully
10070 MAINT_CHANGE_LOCK_DIS_OK GSAL.Ina Change lock disabled successfully
from Maintenance menu
10080 MAINT_61850_DIS_OK GSAL.Ina IEC 61850 disabled successfully
from Maintenance menu
13200 TRANSFER_CONFIG_OK GSAL.Ina Configuration transferred to the
device successfully
13250 CONFIG_MODE_ENTER_OK GSAL.Ina Entered configuration mode
successfully
13260 CONFIG_MODE_EXIT_OK GSAL.Ina Exited configuration mode
successfully
13400 TRANSFER_FIRMW_OK GSAL.Ina Firmware transferred to the device
successfully
13500 READ_FIRMW_OK GSAL.Ina Firmware files read/exported from
the device successfully
13520 TRANSFER_CERTS_OK GSAL.Ina Certificates transferred to the device
successfully
13580 READ_CERTS_OK GSAL.Ina Exported/read certificates from
device successfully
13610 ADD_ENTITY_CERT_OK GSAL.Ina Installed entity certificate
successfully
13620 REMOVE_ENTITY_CERT_OK GSAL.Ina Removed entity certificate
successfully
13630 ADD_TRUST_ANCHOR_CERT_OK GSAL.Ina Installed trust anchor certificate
successfully
13640 REMOVE_TRUST_ANCHOR_CERT_OK GSAL.Ina Removed entity certificate
successfully
14200 TRANSFER_CONFIG_FAIL GSAL.SvcViol Failed to transfer configuration to the
device
14250 CONFIG_MODE_ENTER_FAIL GSAL.Ina Failed to enter configuration mode
14260 CONFIG_MODE_EXIT_FAIL GSAL.Ina Failed to exit configuration mode
14400 TRANSFER_FIRMW_FAIL GSAL.SvcViol Failed to transfer firmware to the
device
14500 READ_FIRMW_FAIL GSAL.Ina Failed to read firmware files from the
device
14520 TRANSFER_CERTS_FAIL GSAL.Ina Failed to transfer certificates to the
device
14580 READ_CERTS_FAIL GSAL.Ina Failed to read certificates from the
device
Section 6 1MRK 511 399-UEN B
User activity logging
84 670 series 2.2 IEC
Cyber security deployment guideline