18
1MRS750500-MUM
Feeder and Machine Terminals
Operators Manual
REF 54_ , REM 54_
4.1. Acknowledgement and resetting of LED indicators, indication
messages, outputs and registers
LED indicators, indication messages, outputs and registers can be acknowledged
and reset regardless of the HMI operation level, view or menu.
LED indicators, indication messages and outputs of protection functions are
acknowledged by pressing [C] and [E] simultaneously for at least 2 seconds. A
message in the assisting window confirms the acknowledgement.
LED indicators, indication messages, outputs of functions and registers,
including the disturbance recorder, are acknowledged by pressing [C] and [E]
simultaneously for at least 5 seconds. A message in the assisting window
confirms the acknowledgement.
Fig. 4.1.-1 Acknowledgement and resetting
C
C
C
E
C
E
kuitsequ
View dependent
reset
LEDs and non-
reset indications
2 sec.
2 sec.
2 sec.
Clears messages
according to view:
MIMIC, MEAS,
EVENT, ALARM,
MAIN MENU
Resets LEDs
and indications
Resets outputs, LEDs
and indications
Resets registers, outputs, LEDs,
indications and waveform memory
Reset/Clear done