EasyManua.ls Logo

ABB SACE PR010/T - PR12 x Series Measuring and History; Measuring Instantaneous Data; Resetting Energy and Measuring History

ABB SACE PR010/T
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ABB SACE SACE PR010/T RH0025002 L2551 16/20
20
6.4 Mechanical specifications
6.5 Standard equipment
The SACE PR010/T test unit is supplied in a special case, complete with the following
accessories:
Plastic enclosure
Front panel protected against electrostatic discharges
Dimensions: Length = 210 mm
Max. width = 120 mm
Max. depth = 60 mm
Protection class: IP30
Weight (complete with rechargeable batteries): 600 g
Operating temperature range: 0 °C ... +50
0
C
Storage temperature range: -20 °C … +70
0
C
Maximum relative humidity: 90%, (non-condensing)
MTBF: 15 years @ 30°C
1. SACE PR010/T test
unit complete with
rechargeable batteries
2. SACE TT1 TRIP
TEST unit
3. External power supply
4. 1m length cables with
connectors suited for
several types of
electronic releases.
5. External power supply
connection cable
6. PC connection cable
7. User manual and
application software
8. Set of adapters for
different types of
releases
9. Batteries

Other manuals for ABB SACE PR010/T