COMPATIBILITY BETWEEN WINDOWS OPERATING SYSTEMS
AND SD-TEST UNIT INTERFACE
Operating
System
Installation
requirements
Operating
requirements
Notes
Windows XP
or earlier
Any user
Any user
Windows 7
Administrator
user
Any user
(1)
(1) Use with “non administrator” profile
can be obtained by installing the latest SD-
Test Bus Interface version available (from file
1SDC200002X0005 15.zip or more recent)
Windows 10
Administrator
user
Administrator
user
ERROR MESSAGES, TROUBLESHOOTING
Updating of faults described in chap. 6.7 of Instruction RH0025002:
Faults
Causes and errors
Checks and remedies
7
Difficulties in
updating PR010/T:
- Display locked on
“updating”.
- Display locked on
start-up screen.
During an update could be
caused by:
- Power outage.
- Cable between PR010/T
and PC has detached.
- Driver of serial line to PC
is locked.
1. Shut down PR010/T and remove
power supplier if connected.
2. Restart PR010/T.
3. Press STOP button within 2s from
powering: this will prepare unit for
re-programming.
4. Comply with instructions on
display.