33
ABB STOTZ-KONTAKT
2CDC 106 008 M5703
D
Auslösekennlinien
E
Tripping characteristics
F
Courbes de déclenchement
S
Utlösningskurvor
I
Caratteristiche di intervento
SP
Curvas características
de disparo
RUS
Характеристики
срабатывания
three
pole
4)
two pole
3)
Multiples of rated current
1)
Tripping time
2)
130.0 ... 158.0 ... 185.0 A
Tripping time
2)
Multiples of rated
current
1)
3 x Ie
6 x Ie
7.2 x Ie
min
three pole
4)
30.0 s
17.0 s
15.4 s
130.0 A
two pole
3)
18.0 s
11.0 s
10.0 s
max
three pole
4)
45.0 s
26.0 s
23.8 s
185.0 A
two pole
3)
23.0 s
14.0 s
13.0 s
three
pole
4)
two pole
3)
Multiples of rated current
1)
Tripping time
2)
165.0 ... 200.0 ... 235.0 A
Tripping time
2)
Multiples of rated
current
1)
3 x Ie
6 x Ie
7.2 x Ie
min
three pole
4)
31.6 s
18.3 s
16.5 s
165.0 A
two pole
3)
17.7 s
10.6 s
9.7 s
max
three pole
4)
47.0 s
28.7 s
26.7 s
235.0 A
two pole
3)
24.0 s
14.3 s
13.3 s
1) 2) 3) 4) 5)
Vielfaches vom Nennstrom Auslösezeit 2-polig 3-polig Sicherung
Multiple du courant de reglage Temps de déclenchement 2 broches 3 broches Fusible
Multipelfaktor för utlösningsström Utlösningstid 2-polig 3-polig Säkring
Multiplo della corrente di regolazione Tempo di apertura Bipolare Tripolare Fusibile
Múltiplos de la intensidad aplicada tiempo de disparo de 2 polos de 3 polos Fusible
Êîýôôèöèåíò òîêà óñòàâêè Âðåìÿ ñðàáàòûâàíèÿ Äâóõïîëþñíûé Òðåõïîëþñíûé Ïðåäîõðàíèòåëü
D
F
S
I
SP
RUS